Poseidon 4002 is a 19" 1U rack mount system for datacenter temperature and environment monitoring. The Poseidon solution monitors racks and computer rooms (temperature, humidity, electricity supply, access to the room, detectors). Alerting works by e-mail, SNMP traps, SMS, output relays.
Poseidon 4002 is a complete system for environment monitoring in a rack or in a datacenter. The 4002 model can be mounted as a 1U device, or outside of the 42U space.
The Poseidon solution monitors a 19" rack or an entire server room.
18 sensors are supported (temperature, humidity, smoke, flood, electricity supply status or failure, entry to the room, digital inputs).
The Poseidon 4002 monitoring system fits into a 19" rack and is SNMP compatible. Two monitoring applications (PD Trigger and HWg-PDMS) are included free of charge.
Alerting to critical situations is performed by e-mail, SNMP Traps, SMS (GSM modem required) and output relays.
The relays can e.g. be used to switch on a backup air-conditioning unit or to restart a server.
Built-in web server, SNMP compatible
Up to 18 sensors can be connected
Humidity, smoke, temperature, flood, vibrations, entry to the room, air flow, water leak, input contacts, etc...
PD Trigger and HWg-PDMS monitoring software free of charge
Ansichten
Was Poseidon 3468 messen kann, passende Sensoren
1-Wire UNI sensors
Total bus length max 30 m
Each sensor has its own SafeRange. When the range is exceeded (alarm), e-mail or SNMP trap is invoked.
Temperature - Temp-1Wire
Humidity - Humid-1Wire
Air flow sensor
Voltage sensor (0..10V)
AC current 0..30A
Hub: T-Box
Dry contact inputs (for detectors):
Water flood detector: Flood detector
Gas leak detector: Gas leak detector
Smoke detector: Smoke detector
Motion detector: Motion detector
Door contact
Digital outputs (relays)
*Electricity supply control: PowerEgg to detect and control 110/230V
Konfigurationshilfen, Programme, Programmierbeispiele mit Sourcecode, SNMP Tool PD Trigger
Configuration: UDP Config - IP address configuration
Event processing: PD Trigger - reacts to events
Monitoring and logging: HWg-PDMS - Monitoring software with MS Excel reporting
Visualization: CapTemp - Process monitoring and control
Other applications: Third-party SNMP software
For programmers: HWg-SDK contains interface descriptions and examples of using M2M protocols in several programming languages
(JAVA, PHP, Borland C++ Builder 6.0, Microsoft Visual C++ 6.0, Borland Delphi 6.0, Microsoft Visual Basic & Excel VBA, VB.NET, C code for Linux, JavaScript (AJAX) Microsoft Visual C# 2005 (.NET))
PD Trigger application example
With the PD Trigger application for Windows, it is possible to receive alarms (SNMP traps) from an unlimited number of Poseidon products and define conditions and actions based on the originating device and the probe name. For example:
In case of air conditioning failure in server room A, send a SMS to Peter
In case of alarm in server room B, send e-mail to Tom
In case of electricity supply failure anywhere, send SMS to Peter and turn on a warning light at the receptionist's desk