HWg ist einer der führenden Hersteller von Raumüberachungssystemen für Temperatur-, Luftfeuchte-, Sensor-Relais-, Luftdruck-, Rauch-, Magnetkontakt-, potentialfreie Kontakt- Sensoren und Ralais over IP Lösungen.
Poseidon 3268, Hw-Group, Raumüberwachung und Monitoring, High End Überwachung. 1 Port für Sensoren oder Kombi- Sensoren
(erweiterbar auf 6). 4 potentialfreie Eingänge. Webinterface, voll SNMP fähig, Email.
The Poseidon model 3268 is a small web server that can send Email, when a contact is switched or when temperature and humidity gets out of preset range. You can also control two relay outputs from web interface and turn off e.g. a server. The model 3268 notifies of an alarm via Email, SNMP Trap or via switching output relay.
Poseidon model 3268 can notice operator of crisis situation in various method (switched on/switched off contact, temperature or humidity out of set range).
When a Alarm occurs, the device sends you Email and notice Your NMS (Network Management Software) over SNMP.
Configuration and current values over graphic WWW interface.
* 2 relay outputs to control external devices
* 4 inputs to connect contact
* You can connect up to 4 temperature or humidity sensors.
* IT bus to connect sensors (over up to 10m), standard phone switch, cables and connectors can be used
* Typical use:
o Switch contact to send email or SNMP Trap to several recipients.
o Turn on external cooling fan and notify an operator after temperature gets out of preset range.
What Poseidon 3268 measures
Sensors are connected over 1-Wire (RJ12), total wiring length must not exceed 10 meters. Each sensor monitors whether the value is in set range (including inputs for connecting contacts). It warns about set range exceeding (Alarm status) via Email or sending SNMP trap.
Compatible probes
Temperature - Temp-1Wire
Temperature probes, different lengths of connecting cables according to ordering number:
600 005 = 3 meters long, 600 242 = 1 meters long, 600 056 = 10 meters long)
Die Poseidon Serie von HW group lässt sich von jedem, auch von unbedarften Benutzern, innerhalb kürzester Zeit und wenigen Minuten aufsetzen. Nachdem die Sensoren angesteckt sind einfach die IP Adresse des Gerätes im Browser öffnen und einloggen. Wie das geht ist ausführlich beschrieben und innerhalb weniger Handgriffe erledigt.
Das Einrichten der Sensoren wird hier gezeigt:
Beschreibung Details:
WEB (HTML)
Values and state of sensors are presented on WWW page. The page is automatically reloaded every 5 second. There is a link to Flash Setup from main HTML page, update FirmWare and others.
XML
All sensor's values as well as alarm status information are available in XML files (temper.xml) and any application can log it from XML tags
SNMP
SNMP is protocol for monitoring of telecommunication devices, network infrastructure and related technology. The Poseidon is fully controllable over SNMP (v1, partially v2
Modbus/TCP
Modbus/TCP is industrial standard for input from sensors and output to visualizing and SCADA systems. All values are available over Modbus/TCP
Alarms
SNMP Traps
In case of exceeding "Safe Range" the sensor gets to Alarm status. To notify of this a SNMP Trap including alarm status description is sent to configured IP address
Email
In case of exceeding "Safe Range" the sensor gets to Alarm status. To notify of this a Email including alarm status description is sent to configured email address
HW interface
Digital Outputs (Relay switch)
2 switching contacts of internal relay (output contact can be used as a NO (Normally Open) or NC(Normally Close))
Digital Input (Dry Contact input)
4x input to connect contact (door for example) or output from relay (pins labled as NO or NC)
IT Bus - RJ12 (1-Wire)
A bus for use in IT, designed to connect temperature and humidity sensors over up to 10m
Technical specification
Port 1: Ethernet RJ 45 - 10BASE-T / 10 Mbit/s
Port 2: SENSORS - 1-Wire bus (RJ12)
Port 3: 4 Dry Contact input for contact connecting
Port 4: 2 switching outputs of internal relay
Power supply : 12V SS
Device setting:
Locally - RS-232 Setup
UDP Config
Over WEB - graphic Flash setup interface
Over SNMP
Port 1 - Ethernet port
+ Interface
RJ45 (10BASE-T) – 10 Mbit or 10/100 Mbit network compatible
+ Supported protocols
IP: ARP, TCP/IP (HTTP, Modbus over TCP), UDP/IP (SNMP)
+ SNMP compatibility
Ver:1.00 compatible, some parts of the ver 2.0 implemented
Port 2 - 1-Wire sensor bus
+ Connector
RJ12 (6 pins - 4 pins used only)
+ Sensors / distance
model 3265 - max. 5 sensors, up to 10 m total
model 3262 - max. 2 sensors, up to 10 m total
Port 3 - Dry contact inputs
+ 4 Contact inputs
Connect it with a contact directly (dry contact).
+ Isolation
Galvanic isolated up to 50V DC
+ Sensor type
NO or NC contact switch
+ Max distance
Up to 30 m
Port 4 - Relay switch outputs
+ 2 Digital outputs
Control via network (Web, XML, SNMP) or signal local alarm
+ Isolation
Relay switch up to 50V DC, max DC current 24V/1A, 50V/0.5A
+ Switch type
3 pins, can be used as NO or NC contact switch
LED Status indicators
+ POWER
Green - power OK
+ LINK & Activity
Yellow - Ethernet connectivity
DIP SWITCH configuration
+ DIP1 - RS--232 Setup mode
Not used
+ DIP2 - Security
ON = Security mode - remote configuration disabled
OFF = Non-Security mode - remote configuration enabled
Physical parameters
+ Voltage requirements
9 - 15V / 250 mA DC
coaxial power connector (barrel), GND on the shield
+ Dimensions
35 x 101.6 x 76.2 [mm] (H x W x D )
+ Weight
150 g
Functional parameters
Device SETUP configuration possibilities
- UDP Config - IP address assign via UDP with using PN Eye
- TCP Setup - Terminal configuration and sensors management
- WWW Setup - HTTP Flash application
- SNMP (just for some parameters)